Guoyan Zheng, Kumar T. Rajamani, Lutz-Peter Nolte Use of a Dense Surface Point Distribution Model in a Three-Stage Anatomical Shape Reconstruction from Sparse Information for Computer Assisted Orthopaedic Surgery: A Preliminary Study. [Citation Graph (0, 0)][DBLP] ACCV (2), 2006, pp:52-60 [Conf]
Guoyan Zheng, Lutz-Peter Nolte Surface Reconstruction of Bone from X-ray Images and Point Distribution Model Incorporating a Novel Method for 2D-3D Correspondence. [Citation Graph (0, 0)][DBLP] CVPR (2), 2006, pp:2237-2244 [Conf]
Xiao Dong, Guoyan Zheng Fully Automatic Determination of Morphological Parameters of Proximal Femur from Calibrated Fluoroscopic Images Through Particle Filtering. [Citation Graph (0, 0)][DBLP] ICIAR (2), 2006, pp:535-546 [Conf]
Xiao Dong, Guoyan Zheng A Computational Framework for Automatic Determination of Morphological Parameters of Proximal Femur from Intraoperative Fluoroscopic Images. [Citation Graph (0, 0)][DBLP] ICPR (1), 2006, pp:1008-1013 [Conf]
Guoyan Zheng, Xuan Zhang A Unifying MAP-MRF Framework for Deriving New Point Similarity Measures for Intensity-based 2D-3D Registration. [Citation Graph (0, 0)][DBLP] ICPR (2), 2006, pp:1181-1185 [Conf]
Guoyan Zheng, Xiao Dong, Lutz-Peter Nolte Robust and Accurate Reconstruction of Patient-Specific 3D Surface Models from Sparse Point Sets: A Sequential Three-Stage Trimmed Optimization Approach. [Citation Graph (0, 0)][DBLP] MIAR, 2006, pp:68-75 [Conf]
Guoyan Zheng, Xuan Zhang, Lutz-Peter Nolte Automatic Pose Recovery of the Distal Locking Holes from Single Calibrated Fluoroscopic Image for Computer-Assisted Intramedullary Nailing of Femoral Shaft Fractures. [Citation Graph (0, 0)][DBLP] MIAR, 2006, pp:195-202 [Conf]
Guoyan Zheng, Xiao Dong Particle Filter Based Automatic Reconstruction of a Patient-Specific Surface Model of a Proximal Femur from Calibrated X-Ray Images for Surgical Navigation. [Citation Graph (0, 0)][DBLP] ACIVS, 2007, pp:616-627 [Conf]
Guoyan Zheng Incorporating Spatial Information into 3D-2D Image Registration. [Citation Graph (0, 0)][DBLP] CAIP, 2007, pp:792-800 [Conf]
Guoyan Zheng Unifying Energy Minimization and Mutual Information Maximization for Robust 2D/3D Registration of X-Ray and CT Images. [Citation Graph (0, 0)][DBLP] DAGM-Symposium, 2007, pp:547-557 [Conf]
Guoyan Zheng, Xiao Dong Automatic Reconstruction of a Patient-Specific Surface Model of a Proximal Femur from Calibrated X-Ray Images Via Bayesian Filters. [Citation Graph (0, 0)][DBLP] ICIC (1), 2007, pp:1094-1102 [Conf]
Guoyan Zheng Reconstruction of Patient-Specific 3D Bone Model from Biplanar X-Ray Images and Point Distribution Models. [Citation Graph (0, 0)][DBLP] ICIP, 2006, pp:1197-1200 [Conf]
Guoyan Zheng, Xuan Zhang A Novel Parameter Decomposition Approach for Recovering Poses of Distal Locking Holes from Single Calibrated Fluoroscopic Image. [Citation Graph (0, 0)][DBLP] SCIA, 2007, pp:364-373 [Conf]
Guoyan Zheng, Xuan Zhang Precise approach for recovering poses of distal locking holes from single calibrated X-ray image for computer-assisted intramedullary nailing of femoral shaft fractures. [Citation Graph (0, 0)][DBLP] VISAPP (Special Sessions), 2007, pp:120-127 [Conf]
Statistical Deformable Model-Based Reconstruction of a Patient-Specific Surface Model from Single Standard X-ray Radiograph. [Citation Graph (, )][DBLP]
Automated Vertebra Identification from X-Ray Images. [Citation Graph (, )][DBLP]
Robust intensity-based 3D-2D registration of ct and X-ray images for precise estimation of cup alignment after total hip arthroplasty. [Citation Graph (, )][DBLP]
Automatic extraction of femur contours from calibrated x-ray images: A Bayesian inference approach. [Citation Graph (, )][DBLP]
Precise Pose Recovery of Distal Locking Holes From Single Calibrated Fluoroscopic Image via a Novel Variable Decomposition Approach. [Citation Graph (, )][DBLP]
An Integrated Approach for Reconstructing a Surface Model of the Proximal Femur from Sparse Input Data and a Multi-Level Point Distribution Model. [Citation Graph (, )][DBLP]
Automatic Extraction of Proximal Femur Contours from Calibrated X-Ray Images Using 3D Statistical Models. [Citation Graph (, )][DBLP]
Unsupervised Reconstruction of a Patient-Specific Surface Model of a Proximal Femur from Calibrated Fluoroscopic Images. [Citation Graph (, )][DBLP]
Effective Incorporation of Spatial Information in a Mutual Information Based 3D-2D Registration of a CT Volume to X-Ray Images. [Citation Graph (, )][DBLP]
Statistically Deformable 2D/3D Registration for Accurate Determination of Post-operative Cup Orientation from Single Standard X-ray Radiograph. [Citation Graph (, )][DBLP]
Automated Intervertebral Disc Detection from Low Resolution, Sparse MRI Images for the Planning of Scan Geometries. [Citation Graph (, )][DBLP]
Automatic Mutual Nonrigid Registration of Dense Surfaces by Graphical Model Based Inference. [Citation Graph (, )][DBLP]
Development of a miniature robot for hearing aid implantation. [Citation Graph (, )][DBLP]
Determining Geometrical Parameters by Particle Filter for Automatic Reconstruction of Surface Model of Proximal Femur from Biplanar Calibrated Fluoroscopic Images. [Citation Graph (, )][DBLP]
Determination of Pelvic Orientation from Ultrasound Images Using Patch-SSMs and a Hierarchical Speed of Sound Compensation Strategy. [Citation Graph (, )][DBLP]
Search in 0.003secs, Finished in 0.364secs
NOTICE1
System may not be available sometimes or not working properly, since it is still in development with continuous upgrades
NOTICE2
The rankings that are presented on this page should NOT be considered as formal since the citation info is incomplete in DBLP